← back

!! NOT FOR OPERATIONAL USE !! data may be stale, incomplete, or wrong


numberJ3399/26 CANCELLED
locationYAMB
begin2026-07-26 22:00 UTC (42d ago)
end2026-07-30 08:00 UTC (39d ago)
CADS id3888115
CADS seq11352262
CADS msgNMS_ID_1784771294767000

raw text:

ENGINE TEST CELL OPS ACT
ENGINE TEST CELL 'ETC1' LOCATED PSN 273854S 1524250E BRG 240 MAG
285M FM THR RWY 33
FLASHING BEACON WILL BE ON DURING ETC1 OPERATION AND NOTIFIED ON ATIS
WHEN ATC IS ACTIVE
ACFT OVERFLYING ETC1 DURING OPERATION MAY EXPERIENCE:
-MOD TURB BELOW 873FT AGL (964FT AMSL) WITHIN 79M
-SEV TURB BELOW 131FT AGL (222FT AMSL) WITHIN 17M
-EXTREME TURB BELOW 66FT AGL (157FT AMSL) WITHIN 9M
PILOTS ARE TO REMAIN VISUALLY CLEAR WHEN BELOW 1000FT AMSL (REMAINING
EAST OF TWY A WILL KEEP FLIGHT PATH CLEAR)
IF UNABLE TO REMAIN VISUALLY CLEAR:
-ADVISE ATC (IF ATC ACTIVE)
-CIRCUIT OPERATIONS NOT AVBL 
-PRACTICE INSTRUMENT APPROACHES NOT AVBL
DURING CTAF ALL IAP PROTECTION SURFACES ARE INFRINGED IAP NOT AVBL IN
IMC, MIL ACFT CONDUCT IAP AT OWN RISK
PLUME HAZARD OCCASIONALLY EXTENDS BEYOND THAT DEFINED ABOVE (EXPECTED
DURATION 2MIN) - ATC WILL ACTIVATE AND PROVIDE SEGREGATION TO
TERMINAL AIR TRAFFIC
NO CONCURRENT CIVIL OPS WHILST ETC1 IS IN OPERATION WITHOUT PRIOR
APPROVAL
ILS-Z AND LOC-Z RWY 15 NOT AVBL TO CIVILIAN ACFT DUE HAZARDOUS PLUME
INFRINGING INSTRUMENT APPROACH PROTECTION SERVICES
ALL REQUESTS FOR CIVIL OPS DURING NOTAM PERIOD ARE TO CONTACT THE AIR
BASE OPERATIONS CENTRE ON TEL: (07) 5361 2888 OR
AMB.ABOC(AT)DEFENCE.GOV.AU
ETC1 MAY BE CONTACTED AT (07) 5362 9628 OR (07) 5362 8678 TO STOP OPS
IF REQUIRED WITH 5MIN PN

icao text:

J3399/26 NOTAMN
 Q) YBBB/QFAXX/IV/NBO/A/000/999/2738S15243E005
 A) YAMB
 B) 2607262200 C) 2607300800
 D) 2607262200 TO 2607270800
    2607272200 TO 2607280800
    2607282200 TO 2607290800
    2607292200 TO 2607300800
 E) ENGINE TEST CELL OPS ACT
 ENGINE TEST CELL 'ETC1' LOCATED PSN 273854S 1524250E BRG 240 MAG
 285M FM THR RWY 33
 FLASHING BEACON WILL BE ON DURING ETC1 OPERATION AND NOTIFIED ON ATIS
 WHEN ATC IS ACTIVE
 ACFT OVERFLYING ETC1 DURING OPERATION MAY EXPERIENCE:
 -MOD TURB BELOW 873FT AGL (964FT AMSL) WITHIN 79M
 -SEV TURB BELOW 131FT AGL (222FT AMSL) WITHIN 17M
 -EXTREME TURB BELOW 66FT AGL (157FT AMSL) WITHIN 9M
 PILOTS ARE TO REMAIN VISUALLY CLEAR WHEN BELOW 1000FT AMSL (REMAINING
 EAST OF TWY A WILL KEEP FLIGHT PATH CLEAR)
 IF UNABLE TO REMAIN VISUALLY CLEAR:
 -ADVISE ATC (IF ATC ACTIVE)
 -CIRCUIT OPERATIONS NOT AVBL 
 -PRACTICE INSTRUMENT APPROACHES NOT AVBL
 DURING CTAF ALL IAP PROTECTION SURFACES ARE INFRINGED IAP NOT AVBL IN
 IMC, MIL ACFT CONDUCT IAP AT OWN RISK
 PLUME HAZARD OCCASIONALLY EXTENDS BEYOND THAT DEFINED ABOVE (EXPECTED
 DURATION 2MIN) - ATC WILL ACTIVATE AND PROVIDE SEGREGATION TO
 TERMINAL AIR TRAFFIC
 NO CONCURRENT CIVIL OPS WHILST ETC1 IS IN OPERATION WITHOUT PRIOR
 APPROVAL
 ILS-Z AND LOC-Z RWY 15 NOT AVBL TO CIVILIAN ACFT DUE HAZARDOUS PLUME
 INFRINGING INSTRUMENT APPROACH PROTECTION SERVICES
 ALL REQUESTS FOR CIVIL OPS DURING NOTAM PERIOD ARE TO CONTACT THE AIR
 BASE OPERATIONS CENTRE ON TEL: (07) 5361 2888 OR
 AMB.ABOC(AT)DEFENCE.GOV.AU
 ETC1 MAY BE CONTACTED AT (07) 5362 9628 OR (07) 5362 8678 TO STOP OPS
 IF REQUIRED WITH 5MIN PN

downloads:


!! NOT FOR OPERATIONAL USE !! data may be stale, incomplete, or wrong

© 2026 coredoes.dev